Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.12767633
- Product Categories
- Friendly Links
Information Name: | 6ES7307-1BA01-0AA0 Siemens adjustment module power supply PS307 model 24V/2A |
Published: | 2014-03-19 |
Validity: | 1000 |
Specifications: | Conventional |
Quantity: | 100.00 |
Price Description: | |
Detailed Product Description: | 6ES7307-1BA01-0AA0 SIMATIC S7-300 Power Supply PS307 adjust input: AC120/230V Output: DC 24 V / 2 A single-phase AC power supply models 24V/2A Input supply voltage / 1 / at AC / rated voltage of 120 V power supply / 2 / at AC / rated voltage range of 230 V / minimum? Remarks adaptive input voltage range / 1 / in time 85 ... 132 V AC input voltage / 2 / at 170 ... 264 V AC when no anti-Wide Input overvoltage rated input capacity of 2.3 × V, power bridging 1.3ms Ia rated at minimum 20 ms break bridging Vin = 93/187 V rating of the power supply frequency 50/60 Hz power frequency range / minimum 47 .. .63 Hz input current / input voltage rating of 120 V 0.9 A when the input current / voltage rating of 230 V 0.5 A switched on when the current limit (+ 25 ° C), max 22 A switched current limit duration / 25 ° C / maximum 3 ms I2t, input fuse max 1 A2 · s installed T 1.6 A/250 V (not available) power line protection devices (IEC 898) recommended MCB: 3A characteristics After the curve C Output adjustment, zero potential nominal DC voltage Ua 24 V DC voltage rating of the total fault tolerance, static static power adjustment ± 3%, about 0.1% of the static load regulation, about 0.2% of the remaining waviness double peak, maximum 50 mV residual waviness double peak, typical dual 5 mV peak to peak, maximum (band broadband approximately 20 MHz) 150 mV peak double peak, typical (band broadband approximately 20 MHz) 20 mV Product function / adjustable output voltage if the output voltage set - 24 V operation green LED display normal startup / shutdown features V output without overshoot (soft start) start delay, maximum 2 s voltage rise, typical 10 ms Ia nominal current rating of 2 A Current Range / Min Short circuit 0 ... 2 A supply of power / typical 48 W transient overload current / start period / typical 9 A overcurrent overload duration / start-shorted 90 ms current instantaneous overcurrent / short circuit during operation / typical 9 A-off short circuit overload duration / 90 ms running parallel to increase power efficiency Ua is the rated capacity, the rated efficiency when Ia, approximately 84% Ua nominal, rated power when Ia, about 9 W dynamic grid loop control adjustment ( Ue rated ± 15%), 0.1% of the maximum dynamic load regulation (Ia: 50/100/50%), Ua ± 0.8% typical load jump from 50 to 100 percent of the regulation time of 0.5 ms typical load jump 100 to 50% of the regulation time, settling time 0.5 ms typ / max 1 ms output overvoltage protection and monitoring of additional control loop in <28.8 V is closed, the automatic restart current limit / minimum 2.2 ... 2.6 A output characteristics / short circuit protection to protect the electronic lock, automatic restart Sustained short circuit current / RMS / max 2 A Overload / Short Show - Safety Primary / Secondary potential isolation is potential isolation to EN SELV output voltage 60950-1 and EN 50178 for Protection class Class I Leakage current / maximum leakage current of 3.5 mA / 0.5 mA CE logo is typical UL / CSA certification is UL / cUL (CSA) license cULus-Listed (UL 508, CSA C22.2 No. 142), File E143289 explosion-proof ATEX (EX) II 3G Ex nA II T4;.. cULus (ISA 12.12.01, CSA C22.2 No.213) Class I, Div 2, Group ABCD, T4, File E330455 FM license Class I, Div 2, Group ABCD, T4 CB license No license shipbuilding S7-300 system in the degree of protection (EN 60529) IP20 EMC emitted interference (radiation) EN 55022 Class B restriction does not apply harmonic noise immunity (immunity) EN 61000-6-2 During operation data Ambient temperature / during operation 0 ... 60 ° C? Remarks natural convection Ambient temperature / during transport -40 ... +85 ° C ambient temperature / storage -40 ... +85 ° C Humidity class according to EN 60721 Climate type 3K3, no condensation mechanism bolted connection technology interface / power input L, N, PE: 0.5 ... 2.5 mm2 1 per screw terminals single / multi-strand interface / output L +, M: every 0.5 ... 2.5 mm2 2 screw terminals interface / auxiliary contact - width / height of the housing 40 mm / 125 mm depth of the housing / of the housing 120 mm Installation width 40 mm mounting height 205 mm weight, about 0.4 kg Features / housing / can order The casing is a fixed type / wall mounting No Fixed Type / No fixed rail mounting type / S7-300 bus-shaped installation is to install the rail can be mounted on the S7 standard rail mounting adapter mechanical attachment (6EP1971-1BA00) Other notes at nominal input voltage and ambient temperature of 25 ℃ parameters (unless otherwise specified) |
Admin>>>
You are the 11645 visitor
Copyright © GuangDong ICP No. 10089450, Wuhan Jin Trading Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 11645 visitor
Copyright © GuangDong ICP No. 10089450, Wuhan Jin Trading Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility