Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.12767633
- Product Categories
- Friendly Links
Information Name: | Siemens 6ES7315-2AG10-0AB0 CPU315-2DPCPU Processor Interface Controller with IMP |
Published: | 2014-03-21 |
Validity: | 1000 |
Specifications: | Conventional |
Quantity: | 100.00 |
Price Description: | |
Detailed Product Description: | 6ES7315-2AG10-0AB0 SIMATIC S7-300, CPU315-2DPCPU, with MPI interface, integrated 24VDC power supply, 128 KB working memory, interface 2 DP-Master / slave state a hardware product with a package from engineering system with STEP 7 Hardware update V 5.2 + SP1 from the supply voltage DC 24 V is permissible range, lower limit (DC) 20.4 V permissible range, upper limit (DC) 28.8 V External protection for supply cables (recommendation) Min 2 A Input current Current consumption (rated) 0.8 A Current consumption (no load), 60 mA typical switched current / typical 2.5 A I2t 0.5 A2 · s loss of power Active power loss / typical 2.5 W Memory Memory Type other working memory integrated 128 kbyte; for program and data memory expandable No Load pluggable (MMC) is a plug-in (MMC), data management on the maximum 8 Mbyte MMC (after last programming), min 10 a buffer exists; through MMC guarantee (maintenance) without batteries is; program and data CPU-processing times for bit operations, typical 0.1 μs for word operations, typical 0.2 μs for fixed-point arithmetic, typ 2 μs for floating point arithmetic, typ 3 μs CPU-assembly component count (total) 1024; (DB, FC, FB, OB, SDB) by installing the MMC can reduce the maximum number of loadable blocks. DB Number, max 1023; figures range: 1-1023 capacity, max 16 kbyte number of FB, max 1024; figures range: 0-2047 capacity, max 16 kbyte FC Number, max 1024; numeric range: 0 to 2047 capacity, max 16 kbyte OB capacity, max 16 kbyte number of free cycle OB 1; OB 1 Number of time alarm OB 1; OB 10 OB delayed alarm number 1; OB 20 OB wake warning number 1; OB 35 Number of process alarm OB 1; OB 40 DPV1 alarm OB number 3; OB 55,56,57 startup OB number 1; OB 100 Number of asynchronous error OB 1; OB 80 OB synchronization error number 2; OB 121,122 nesting depth per priority class 8 Additional error OB Level 4 counters, timers and S7 counters 256 Number of remanence remanence is adjustable upper limit 0 8 255 count range adjustable preset limit 0 upper limit is the presence of a type 999 IEC counter does not limit the number of SFB (only by RAM limit) S7 256 times the number of residual magnetism is adjustable preset limit 0 upper limit 255 no remaining time 10 ms upper limit 9990 s IEC timer existence is not to limit the number of types of SFB (only by RAM capacity) Data areas and their retentivity retentive data area, total number of all markers, the presence of residual magnetism is the maximum 2048 byte; MB 0 to MB 2047 preset number remanence MB 15 MB 0 timed to mark 8; 1-byte data tag the number of components, max 1023; figures range: 1-1023 capacity, max 16 kbyte remanence is adjustable; does not remain in the DB remanence is characterized by default local data per priority class, max 1024 byte; each The maximum range of 510 Peripheral Component address inputs 2 kbyte address range output of 2 kbyte distributed inputs 2 kbyte output of 2 kbyte Process image Inputs 128 byte 128 byte output of the digital output of the channel inputs 16384 16384 inputs, which focused output of type 1024, which centralized analog channel inputs 1024 1024 1024 output of inputs, of which central 256 Outputs, of which central 256 Hardware Expansion Expansion devices, max 3 DP master station number 1 on CP 4 can run FM and CP (recommended) FM 8 CP, point 8 CP, LAN 10 component vector component carrier, max 4 Number of units / per module subrack / maximum 8 Time Clock Hardware clock (real-time clock) Yes daily deviation, maximum value 10 s buffer duration 6 wk; run when the ambient temperature is 40 ° C when the time counter 1 Number / Number range 0 0-2 ^ 31 hours (when using SFC 101) Granularity 1 hour is the time synchronization Support is provided on the MPI, the master is on the MPI, the slave is in the DP, the main station is; in DP slave only time from standing DP, slave in the AS, the main station in the AS , the slave No Ethernet input on integrated channels (DI) 0 integrated channel digital output (DO) 0 integrated channel analog input (AI) whether the numbers 0 through NTP integrated channel analog output (AO) 0 Number of parallel interfaces Interface 0 20 mA Number of interfaces (TTY) 0 RS 232 ports quantity 0 RS 422 interfaces 0 Number of other interfaces number 01. interface Physics RS 485 galvanically isolated power supply (15 to 30 V DC) No interface, maximum 200 mA Functionality MPI DP master No DP slave No point connection No MPI transmission rate of the number of connections 16, max 187.5 kbit / s service PG / OP communication is a global data communications are routed S7 basic communication Yes S7 communication Yes S7 communication, as client No S7 communication, as server is 2 RS 485 interface Physics is galvanically isolated power supply (15 to 30 V DC) interface, maximum 200 mA Functionality MPI No DP master is a DP slave is whether the Local Operating Network DP master Number of connections, the maximum transmission rate of 16, max 12 Mbit / s DP slaves, max 124; each site service PG / OP communication is whether the route is a global data communication S7 basic communication Yes; just smart block S7 communication Yes S7 communication, as client No S7 communication, as server support is equidistant whether SYNC / FREEZE is DPV1 is the address of the input range, maximum output of 2048 byte maximum 2048 byte valid data for each DP slave inputs, maximum output of 244 byte maximum number of connections 16 244 byte DP slave transmission rate, maximum 12 Mbit / s Automatic baud rate search is; only for passive interface address range, maximum 32 for each address range valid data, maximum 32 byte Services PG / OP communication Yes Routing Yes; interface in active global data communication No S7 basic communication No S7 communication Yes S7 communication, as client No S7 communication, as server is a direct data exchange (lateral connection) is DPV1 No memory inputs 244 byte transmit output of 244 byte communication functions PG / OP communication is to provide support for global data communication is the number of GD circles, max 8 GD packet number, the maximum number of 8 GD packets, transmitter, max Value 8 GD packet number, the receiver, maximum 8 GD packet size, maximum 22 byte GD packet size (consistency), maximum 22 byte S7 basic communication support is valid data for each task, the maximum 76 byte per task of valid data (consistency), maximum 76 byte; 76 bytes (for X_SEND or X_RCV); 64 bytes (or X_GET as a server for X_PUT) S7 communication as server is supported as a client is; through CP and loadable FB valid data for each task, the maximum 180 byte; For PUT / GET valid data for each task (consistency), max 64 byte; S5-compatible communication as server provides support; via CP and Load all 16 FC number of connections available for PG communication 15 reserved for PG communication 1 Adjustable for PG communication, min 1 Adjustable for PG communication, max 15 usable for OP communication 15 reserved for OP communication 1 can Adjustment for OP communication, min 1 adjustable for OP communication, max 15 can be applied to S7 basic communication S7 Basis Communication reserved 12 0 adjustable for S7 Basis Communication, minimum 0 adjustable for S7 basic the number of registered sites can communicate, max 12 can be used for message routing 4 S7 messaging features, maximum 16; depending on the PG / OP and S7 basic communication configuration connection process diagnostic messages are active at the same time the alarm S components, maximum of 40 components of the state debug function test is the number of points of each step is to stop 2 status / control variable status / control variable inputs, outputs, markers, DB, timers, counters the number of variables, max 30 which state variables, max. 30 of which control variable, max 14 mandatory mandatory mandatory, variable input, the number of output variables, max 10 Diagnostic buffer present Yes Number of entries, max 100 adjustable No Configuration Configuration software STEP 7 is; from the supplied hardware Updated V 5.2 SP1 from program operation standby see instruction list Nesting levels 8 System functions (SFC) see instruction list system functional components (SFB) see instruction list programming language KOP is FUP is AWL is SCL is CFC Yes GRAPH Yes HiGraph? technology to protect user program protection / password protection is Dimensions Width 40 mm Height 125 mm Depth 130 mm Weight Weight about 290 g Date 6ES7315-2AG10-0AB0 SIMATIC S7-300, CPU315-2DPCPU, with MPI interface, integrated 24VDC power supply, 128 KB working memory, interface 2 DP-Master / Slave |
Admin>>>
You are the 11645 visitor
Copyright © GuangDong ICP No. 10089450, Wuhan Jin Trading Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 11645 visitor
Copyright © GuangDong ICP No. 10089450, Wuhan Jin Trading Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility