Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.12767633

- Product Categories
- Friendly Links
Information Name: | 6ES7315-2EH13-0AB0 Siemens CPU315-2PN/DP Ethernet card processor control module |
Published: | 2014-03-21 |
Validity: | 1000 |
Specifications: | Conventional |
Quantity: | 100.00 |
Price Description: | |
Detailed Product Description: | 6ES7315-2EH13-0AB0 SIMATIC S7-300 CPU315-2PN/DP, the central processing unit with 256 KB working memory, interface 1 MPI / DP, 12MBIT / S, Interface 2, Ethernet PROFINET, 2.5 A switched current / typical 2.5 A switched current pulse I2t 1 A2 · s I2t 1 A2 · s loss of power Active power loss / typical 3.5 W Memory Memory Type other working memory integrated 256 kbyte; for program and data memory expandable No Load pluggable (MMC ) is a plug-in (MMC), data management on the maximum 8 Mbyte MMC (after last programming), min 10 a buffer exists; without battery guaranteed by MMC (maintenance-free) is; programs and data CPU - processing times for bit operations, typical 0.1 μs for word operations, typical 0.2 μs for fixed-point arithmetic, typ 2 μs for floating point arithmetic, typ 3 μs CPU-assembly component count (total) 1024; (DB, FC , FB); installed MMC can reduce the maximum number of loadable blocks. DB Number, max 1023; figures range: 1-1023 capacity, max 16 kbyte number of FB, max 1024; figures range: 0-2047 capacity, max 16 kbyte FC Number, max 1024; numeric range: 0 to 2047 capacity, max 16 kbyte OB capacity, max 16 kbyte number of free cycle OB 1; OB 1 Number of time alarm OB 1; OB 10 OB delayed alarm number 1; OB 20 OB wake warning number 1; OB 35 Number of process alarm OB 1; OB 40 DPV1 alarm OB number of 3; OB 55,56,57 isochronous mode Ob number 1; OB 61 OB start number 1; OB 100 Number of asynchronous error OB 6; OB 80,82,83,85,86, 87 Number of synchronous error OB 2; OB 121,122 nesting depth per priority class 8 additional level of error OB 4 counters, timers and S7 counters 256 Number of remanence remanence is adjustable preset limit 0 upper limit 255 8 Count adjustable range is 0 upper limit 999 IEC counter presence is not limiting the number of types of SFB (only by RAM restrictions) S7 256 times the number of residual magnetism is adjustable preset limit 0 upper limit 255 no remaining time 10 ms upper limit 9990 s IEC timer existence is not to limit the number of types of SFB (only limited by RAM) Data areas and their remanence can retain data range, all All, 128 KB maximum number of markers, the presence of residual magnetism is the maximum 2048 byte; MB 0 remanence default to MB 2047 MB ??0 to MB 15 Number of clock memories 8; 1 byte Data blocks Number, max 1023; figures range: 1-1023 capacity, max 16 kbyte remanence is adjustable; in DB feature does not keep the default is the local data remanence each priority class, max 1024 byte; maximum 510 address range for each component peripheral inputs 2 kbyte address range output of 2 kbyte distributed inputs 2 kbyte output of 2 kbyte Process image Inputs 2048 byte 2048 byte output of the input, the output of the adjustable 2 kbyte, adjustable 2 kbyte Inputs, default 128 byte Outputs, preset number of 128 byte component process image component process image, max a digital output of channel inputs 16384 16384 Inputs, of which central 1024 Outputs, of which central channel analog inputs 1024 1024 1024 output of inputs, of which central 256 Outputs, of which central 256 hardware expansion expansion devices, max 3 DP master number one on FM and CP (recommended) CP 4 can run FM 8 CP, point 8 CP, LAN 10 component vector component carrier, max 4 Number of units / per module subrack / maximum 8 hours Clock Hardware clock (real-time clock) is a daily deviation, maximum duration of 10 s buffer 6 wk; run when the ambient temperature is 40 ° C when the time counter 1 Number / Number range 0 0-2 ^ 31 hours of (using 101 SFC) Granularity 1 hour time synchronization is to provide support in the MPI, the master is on the MPI, slaves in the DP, the main station is; in DP slave only time from standing DP , the slaves are in AS, master Yes in AS, slave Yes on Ethernet via NTP is; as a client integrated channel digital input (DI) 0 integrated channel digital output (DO) 0 integrated analog input channels ( AI) 0 integrated channel analog output (AO) 0 Interface Parallel ports quantity 0 20 mA number of interfaces (TTY) 0 RS 232 ports quantity 0 RS 422 interfaces 0 Number of other interfaces number 01. interface Physics RS 485 interface is galvanically isolated power supply (15 to 30 V DC), max 200 mA Functionality MPI Yes DP master is a point to point connection DP slave MPI whether the number of connections 16 transmission rates, maximum 12 Mbit / s service PG / OP communication is routed is a global data communication is S7 basic communication Yes S7 communication Yes S7 communication, as client No S7 communication, as server is the DP master transmission rate, max 12 Mbit / s DP slaves, max 124 service PG / OP communication Routing is a global data communication is whether S7 basic communication Yes; just smart block S7 communication Yes S7 communication, as client No S7 communication, as server is equidistant support Yes SYNC / FREEZE Yes Activation / deactivation of DP slaves are DPV1 is the address range of inputs, maximum output of 2 kbyte, max 2 kbyte each DP valid data inputs from the station, the maximum output of 244 byte maximum 244 byte DP slave transmission rate, max 12 Mbit / s Automatic baud rate search is; only for passive interface address range, maximum 32; maximum of 32 bytes each service PG / OP communication Yes Routing Yes; only active interfaces for global data communication No S7 basic communication No S7 communication Yes S7 communication, as client No S7 communication, as server is a direct data exchange (lateral connections) are DPV1 No memory inputs 244 byte transmit output of 244 byte 2 interface Physics Ethernet RJ45 Isolated Yes Product function / [nicht versorgt -. an der Schnittstelle 2] / [nichtversorgt-Autosensing] is a functional MPI No DP master No DP slave No PROFINET IO controller PROFINET CBA PROFINET IO device is not open IE communication is a network server is a Local Operating Network No PROFINET IO Controller 100 Mbit / s 128 transmission cycle 1 ms update time 1 至 512 ms (PROFINET IO communication components depending on the setting of the minimum value, depending on the number of IO devices and the number of valid data configuration) is S7 communication services are; with loadable FB, you can configure up connections: 14, 32 Maximum number of instances Open IE communication is; via TCP / IP, ISO on TCP, UDP address range inputs, max 2 kbyte Outputs, max 2 kbyte valid data consistency maximum 254 byte PROFINET CBA acyclic transmission is the transmission cycle is communication functions PG / OP communication is to provide support for global data communication is the number of GD circles, max 8 GD packet number, the maximum number of 8 GD packets, transmitter, max. 8 GD packet number, the receiver, maximum 8 GD packet size, maximum 22 byte GD packet size (consistency), maximum 22 byte S7 basic communication support is valid data for each task, the maximum 76 byte each valid data tasks (consistency), max 76 byte; 76 bytes (for X_SEND or X_RCV); 64 bytes (or X_GET as a server for X_PUT) S7 communication as server is supported as a client is; through integration PROFINET interface and loadable FB, or via CP and loadable FB valid data for each task, the maximum value of the STEP 7 online help (SFB / FB S7 communication and SFC / FC of common parameters) S5-compatible communication provides support; through CP and loadable FC Open IE communication TCP / IP is; via integrated PROFINET interface and loadable FB Number of connections, max 8 data length, maximum 1460 byte Number of connections, max 8 ISO-on-TCP (RFC1006) is data length, maximum 8192 byte UDP is; via integrated PROFINET interface and loadable FB Number connection, max 8 data length, maximum 1472 byte PROFINET CBA (when setting the nominal communication load) CPU communication load rated setting 50 1000 Total number of all incoming master remote interconnected group of 32% master / slave function number 30 all master / slave connection / data connection length from the station, maximum 4000 byte leave all master / slave connection data length, maximum 4000 byte internal device number 500 and PROFIBUS devices interconnected internal and PROFIBUS interconnections data length, maximum 4000 byte data length per connection, max 1400 byte using non-cyclic transmission remote interconnection Scanning Frequency: scan interval, the number of minimum 500 ms into the interconnect 100 Number of outgoing interconnections 100 Data length of all incoming interconnections, max 2000 byte Data length of all outgoing interconnections, max 2000 byte per connection data length, maximum 1400 byte transmitted remotely using a loop interconnecting transmission frequency: the number of the number of transmit interval, minimum 10 ms into interconnection interconnection 200 200 leaving the data length of all incoming interconnections, max 2000 byte all leave data length interconnects, maximum 2000 byte length of each data connection, max 450 byte of HMI variables via PROFINET (acyclic) HMI variables can register the number of sites (PN OPC / iMap) 3; 2 个 PN OPC / iMap Data length a number of updates HMI variables 500 ms HMI variables 200 all HMI variables, max 2000 byte PROFIBUS proxy functionality to support the number of linked PROFIBUS devices 16 connected to each data length, maximum 240 byte; depends from All 16 stations the number of connections available for PG communication 15; max reserved for PG communication 1 Adjustable for PG communication, min 1 Adjustable for PG communication, max 15; 1-15 15 is available for OP communication 1 adjustable for OP communication reserved for OP communication, min 1 adjustable for OP communication, max 15; 1-15 can be used in S7 basic communication S7 Basis Communication reserved 14 0 adjustable for S7 Basis Communication minimum 0 adjustable for S7 basic communication, max 14; 0-14 can be used for routing X1 as MPI: Maximum 10; X1 as DP master: Maximum 24; X1 as a DP slave (activated): Up to 14; X2 as PROFINET: Maximum 24 S7 messaging message function can register the number of sites, max 16; depending on the PG / OP and S7 basic communication configuration connection process diagnostic messages are active at the same time the alarm S component, max 40 Debugging functional testing of each component state is step number two is the stopping point status / control variable status / control variable inputs, outputs, markers, DB, timers, counters the number of variables, max 30 variables which state, in which the maximum value of 30 variable control, maximum 14 mandatory mandatory mandatory, variable input, the number of output variables, max 10 Diagnostic buffer present Yes Number of entries, max 500 adjustable No configuration where power outages Insurance 100 configuration software STEP 7 is; from V 5.4 SP2 from the backup device programming operations refer to the list of actions clamping layer 8 system functions (SFC) see instruction list system functional components (SFB) see instruction list programming language KOP is FUP is AWL is SCL is CFC Yes GRAPH Yes HiGraph? technology protect the user program protection / password protection is Dimensions Width 80 mm Height 125 mm Depth 130 mm Weight Weight about 460 g Date 2014-2-10 6ES7315-2EH13-0AB0 SIMATIC S7-300 CPU315-2PN/DP, the central processing unit with 256 KB working memory, interface 1 MPI / DP, 12MBIT / S, Interface 2, Ethernet PROFINET, |
Admin>>>
You are the 11645 visitor
Copyright © GuangDong ICP No. 10089450, Wuhan Jin Trading Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 11645 visitor
Copyright © GuangDong ICP No. 10089450, Wuhan Jin Trading Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility