Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.12767633
- Product Categories
- Friendly Links
Information Name: | 6ES7317-6FF03-0AB0 Siemens central processor CPU317F-2DP |
Published: | 2014-03-25 |
Validity: | 1000 |
Specifications: | Conventional |
Quantity: | 85.00 |
Price Description: | |
Detailed Product Description: | 6ES7317-6FF03-0AB0 SIMATIC S7-300, CPU317F-2DP, the central processing unit with 1024 KB working memory, interface 1 MPI / DP, 12MBIT / S, 2 DP-Interface master / slave memory memory type other working memory Integrated 1024 kbyte expandable No Load memory pluggable (MMC) is a plug-in (MMC), data management on the maximum 8 Mbyte MMC (after last programming), min 10 a buffer exists; guaranteed by MMC (maintenance) without batteries is; program and data CPU-processing times for bit operations, typ 0.05 μs for bit operations, max 0.05 μs for word operations, typical 0.2 μs for fixed-point arithmetic, typical 0.2 μs for floating point operations, typ 1 μs CPU-assembly component count (total) 2048; (DB, FC, FB); installed MMC can reduce the maximum number of loadable blocks. DB Number, max 2047; figures range: 1-2047 capacity, max 64 kbyte number of FB, max 2048; figures range: 0-2047 capacity, max 64 kbyte FC Number, max 2048; numeric range: 0 to 2047 capacity, max 64 kbyte OB operating instructions refer to the list of capacity, max 64 kbyte Number of free cycle OB 1; OB 1 Number of time alarm OB 1; OB 10 OB delayed alarm number 2; OB 20, 21 Wake warning OB 4; OB 32,33,34,35 process alarm OB 1; number of OB 40 DPV1 alarm OB 3; When OB 55,56,57 and other modes Ob number 1; OB 61 OB start number 1; OB 100 Number of asynchronous error OB 5 ; OB 80,82,85,86,87 synchronous error OB number 2; OB 121,122 nesting depth for each priority class error OB 16 additional Level 4 counters, timers and their retentivity S7 counter Number 512 without with battery adjustable retention is adjustable preset 8 remanence is 511 preset upper limit 0 8 0 count range adjustable upper limit is the presence of a type 999 IEC counter does not limit the number of SFB (only limited by RAM ) S7 512 times the number of reservations in the case is without battery adjustable upper limit 0 0 511 remanence adjustable upper limit is 511 preset no remaining time 10 ms upper limit 9990 s IEC timer exists a number of types of SFB Without limiting (only limited by RAM) Data areas and their remanence can retain data range, all All, max 256 kb marker number, max 4096 byte presence of residual magnetism is the default remanence MB 0 to MB 15 Number of clock 8; number one tag byte data components, max 2047; from DB 1 to DB 2047 capacity, max 64 kbyte remanence is adjustable; does not remain in the DB default remanence is characterized by local data per priority class , maximum 1024 byte address range peripheral inputs 8 kbyte address range output of 8 kbyte distributed inputs 8 kbyte output of 8 kbyte Process image Inputs 1024 byte 1024 byte output of digital output of channel inputs 65536 65536 input which central 1024 Outputs, of which central channel analog inputs 1024 4096 4096 output of inputs, of which central 256 Outputs, of which central 256 Hardware Expansion Expansion devices, max 3 component carrier, max 4 each component vector components, the maximum number of integrated 2 8 DP master can run on CP 4 FM and CP (recommended) FM 8 CP, point 8 CP, LAN 10 Time Clock Hardware clock (real-time clock) is buffered and synchronization Daily deviation, maximum duration of 10 s buffer 6 wk; When the ambient temperature is 40 ° C when running hours counter Number 4 Number / Number 0-3 range 0 to 2 ^ 31 hours (when using SFC 101 ) interval is 1 hour retentive; must restart time synchronization support is provided every time you restart the MPI, the main station is on the MPI, the slave is in the DP, the main station is; in DP slave only time from Standing on the DP, slave in the AS, the main station is in AS, the slave is integrated channel digital input (DI) 0 integrated channel digital output (DO) 0 integrated channel analog input (AI) 0 integrated analog output channels (AO) 0 Interface Parallel ports quantity 0 20 mA number of interfaces (TTY) 0 RS 232 ports quantity 0 RS 422 interfaces 0 Number of other interfaces number 01. Interface Interface Type Integrated RS 485 interface Physics RS 485 interface for potential isolation is Power supply (15 to 30 V DC), max 200 mA Functionality MPI Yes DP master is DP slave MPI connection is point to point connection No number 32 transmission rates, maximum 12 Mbit / s service PG / OP communication is routed is Global data communication is S7 basic communication Yes S7 communication Yes S7 communication, as client No S7 communication, as server is the DP master transmission rate, max 12 Mbit / s DP slaves, max 124 service PG / OP communication is Routing is a global data communication No S7 basic communication S7 communication is the S7 communication, as client No S7 communication, as server is equidistant supports isochronous mode is whether the SYNC / FREEZE Yes Activation / deactivation of DP slaves are DPV1 is the address range of the input end, the maximum output of 244 byte maximum 244 byte DP slave transmission rate, max 12 Mbit / s Automatic baud rate search is; only for passive interface address range, max 32 valid data for each address range, maximum of 32 byte service routing is; only active interfaces for global data communication No S7 basic communication S7 communication is a S7 communication, as client No S7 communication, as server is a direct data exchange (lateral connections) are DPV1 No Transmission memory inputs 244 byte output of 244 byte 2. Interface Interface type RS 485 interface Physics Integrated RS 485 is galvanically isolated power supply (15 to 30 V DC) interface, maximum 200 mA Functionality MPI No DP master is a DP slave the Local Operating Network No DP master Number of connections, max 32 transfer rate, maximum 12 Mbit / s DP slaves, max 124 service PG / OP communication is routed is a global data communication No S7 basic communication S7 communication is a S7 communication, as client No S7 communication, as server is equidistant support is isochronous mode is; OB 61 SYNC / FREEZE Yes Activation / deactivation of DP slaves DPV1 is the address range is the input, the output of the maximum 244 byte maximum value of 244 byte DP you can get the latest GSD file from the following pages from the number of connections Station 32 GSD file: http://www.siemens.de/profibus-gsd transfer rate, maximum 12 Mbit / s Automatic baud rate search is; only for passive interface address range, max 32 valid data for each address range, maximum 32 byte Services PG / OP communication Yes Routing Yes; interface in active global data communication No S7 basic communication S7 communication Yes S7 communication is , as client No S7 communication, as server is a direct data exchange (lateral connections) are DPV1 No memory inputs 244 byte transmit output of 244 byte communication functions PG / OP communication is to provide support for global data communication is the number of GD circles, max. 8 GD packet number, the maximum number of 8 GD packets, transmitter, max 8 GD packet number, the receiver, maximum 8 GD packet size, maximum 22 byte GD packet size (consistency), maximum 22 byte S7 basic Communications support is valid data for each task, the maximum 76 byte valid data for each task (consistency), maximum 76 byte; 76 bytes (for X_SEND or X_RCV); 64 bytes (or X_GET as for X_PUT server) S7 communication as server is supported as a client is; via CP and loadable FB valid data for each task, the maximum 180 byte; For PUT / GET valid data for each task (consistency), the maximum 160 byte; S5-compatible communication as server provides support; via CP and loadable FC Number 32 can be used to connect all 31 PG communication reserved for PG communication 1 Adjustable for PG communication, min 1 Adjustable for PG communication maximum 31 usable for OP communication 31 reserved for OP communication 1 adjustable for OP communication, min 1 adjustable for OP communication, max 31 can be applied to 30 of S7 basic communication S7 Basis Communication can be reserved 0 the number of registered sites can be adjusted for S7 Basis Communication, minimum 0 adjustable for S7 basic communication, max 30 can be used to route 8 S7 messaging messaging features, maximum 32; depending on the PG / OP and S7 basic communication Configuration of the connection process diagnostic messages are active at the same time the alarm S component, max 60 debug function test component state is the number of points of each step is to stop 2 status / control variable status / control variable inputs, outputs, markers, DB, timing , a number of counter variable, max 30 variables which state variables which control the maximum 30, maximum 14 mandatory mandatory mandatory, variable input, the number of output variables, max 10 Diagnostic buffer present Yes Number of entries, max. 100 adjustable No Configuration Configuration software STEP 7 is; starting from V 5.2 SP1 backup device programming operations see instruction list Nesting levels 8 System functions (SFC) see instruction list system functional components (SFB) see instruction list programming language KOP is FUP is AWL is SCL is CFC Yes GRAPH Yes HiGraph? technology to protect user program protection / password protection Yes Dimensions Width 80 mm Height 125 mm Depth 130 mm Weight Weight about 460 g Date 2014-1-25 SIMATIC S7-300, CPU317F -2DP, the central processing unit with 1024 KB working memory, interface 1 MPI / DP, 12MBIT / S, 2 DP-Interface master / slave, |
Admin>>>
You are the 11645 visitor
Copyright © GuangDong ICP No. 10089450, Wuhan Jin Trading Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 11645 visitor
Copyright © GuangDong ICP No. 10089450, Wuhan Jin Trading Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility